Frequently bought together:
Description
Features:
| CATEGORY | SPECIFICATIONS |
|---|---|
| Product Type | Hall Effect Water Flow Sensor |
| Application | Water heaters, printers, automatic water machines, flow metering systems |
| Working Principle | Hall effect sensor with pulse output from impeller rotation |
| Material Features | Stainless steel ball in impeller (wear-resistant), sealed structure (anti-leak) |
| Design Structure | Up/down pressure sealing structure for improved leak prevention |
| Flow Range | 0.3 – 6 L/min |
| Water Pressure | ≤ 0.8 MPa |
| Working Voltage Range | DC 5 – 18V |
| Minimum Voltage | DC 3.5V (rated 5V–24V versions available) |
| Maximum Current | 15 mA (at DC 5V) |
| Load Capacity | ≤ 10 mA (DC 5V) |
| Output Signal | Pulse signal (digital output) |
| Operating Temperature | ≤ 80°C |
| Medium Temperature | ≤ 120°C |
| Operating Humidity | 35% – 90% RH (no frost) |
| Storage Temperature | -25°C to 80°C |
| Storage Humidity | 25% – 95% RH |
| Installation | Vertical installation; tilt angle ≤ 5° |
| Sensor Protection | Encapsulated Hall element to prevent leakage and aging |
| Dimensions | 5.8 × 3.4 × 2.6 cm |
| Interface Diameter | Outer: 7 mm, Inner: 3.5 mm |
| Wiring | Red (VCC), Black (GND), Yellow (Signal Output) |
| Durability Feature | Wear-proof impeller with stainless steel ball |
Package Includes:
1pc x YF-S401 Water Flow Sensor