Description
Features:
| CATEGORY | SPECIFICATIONS |
|---|---|
| Product Type | Digital Temperature Controller |
| Weight | 41 g |
| Size | 78 × 51 mm (Length × Width) |
| Temperature Range | -9°C to 99°C |
| Temperature Measurement Accuracy | ±1°C |
| Control Accuracy | ±1°C |
| Setting Range | -9°C to 99°C |
| Refresh Frequency | 0.5 seconds |
| Input Power | DC 9V – 15V |
| Environmental Requirements | Temperature: -10°C to 60°C; Humidity: 20% – 85% |
| Measurement Input | NTC 3950-10K 1% waterproof sensor |
| Output Type | Relay output |
| Relay Capacity | 220V 10A / 12V 10A |
| Display | 3 LED windows: Start Temp, Real-time Temp, Stop Temp |
| Operation | Automatic switching between heating and cooling modes |
| Device Control | Relay output can control up to 1000W devices |
| Installation | Easy to install |
| Technology | Advanced micro-computer based |
Package Includes:
- 1 x Temp Controller
- 1 x NTC 5m Temp sensor
- 1 x Manual Instruction
Manual instruction:
- Start high temperature - cooling mode: when value of set starting value > stopping temperature while detecting temperature ≥ starting temperature, relay close and cooling equipment start working. When detecting temperature ≤ stopping temperature, relay disconnect and cooling equipment stop working. For example: Set starting temperature at 30℃,stopping temperature at 25℃,when detecting temperature value ≤25℃, relay disconnect and indicator lamp (blue)stop lighting.
- Start low temperature-heating mode: when value of set starting temperature <stopping temperature, and detecting temperature ≤starting temperature, relay close and heating equipment start working. Detecting temperature ≥stopping temperature, relay disconnect and heating equipment stop working. For example, set starting temperature at 25℃,stop temperature at 30 ℃.while detecting temperature ≤25℃,relay close and start indicator lamp (red )lighting. When detecting temperature ≥30 ℃,relay disconnect and stop indicator lamp (green) lighting.
Note
- Start indicator lamp: Start(red) indicator lamp, means relay close and equipment start working. Stop indicator lamp: Stop(green)indicator lamp, means relay disconnect and equipment stop working.
- Digital tube: Middle red digital tube displaying present detected temperature.
- Left green digital tube is set starting temperature
- Right green digital tube is set stopping temperature
- Press keyboard START to set starting temperature
- Press keyboard STOP to set stopping temperature.

Start high temperature-cooling mode, set starting temperature value> stop temperature value, when testing temperature≥ starting temperature, relay close and cooling equipment start working. When detecting temperature≤ Stopping temperature, relay disconnect and cooling equipment stop work. For example: Set starting temperature at 30℃,stopping temperature at 25℃,when tested temperature ≤25℃,relay disconnecting and stop indicator lamp (blue) bright.

Start low temperature, heating mode: set starting temperature <stop temperature, when detecting temperature ≤starting temperature, relay close and heating equipment start working
When detecting temperature ≥stopping temperature, relay disconnect and heating equipment stop working, For example: set temperature at 25℃,stop temperature at 30℃,when detecting temperature ≤25℃,relay close and indicator lamp (red) bright.