Frequently bought together:
Description
Order Code: 46579
Name: SCR Application Trainer
SPECIFICATION
SCR application trainer has been designed specifically for the study of SCR & Triac application. This training board gives better understanding of SCR, triac, UJT & Diac as used in various applications. Practical experience on this board carries great educative value for Science and Engineering Students.
OBJECT:-
OBJECT:-
To study the following D.C. Circuit Breaker
- DC Circuit Breaker
- To Study SCR Turn Off Action Under Varying Loads
- To Study DC Over Voltage Current Trip Action
- Lamp Flasher
- Symmetrical SCR Type DC Flasher
- High Power AC Flasher
- AC Phase Control
- Half Wave Phase Control
- Full Wave Phase Control
- UJT Relaxation Oscillator
- Thyristor Alarms
- Study of Make-to-operate Alarms
- Study of Break- To-operate Alarms
- Demonstration of Temper-proof Burgler Alarm
- Time Delay Relay
- Study of Delayed Turn-’ON’ of DC Load
- Study of Auto Turn-’OFF’ of DC Load
- Light Activated Solid State Switch
- Light Operated Switch/relay
- To Demonstrate Lift Activated Relay
- Temperature Controller
- To Turn ON or OFF an External Load At A Particular Temperature
- To Control And Maintain The Temperature of The Internal oven
- Illumination Control Using Scr
- Application of a Triac For Illumination Control
- Study of An Electronic Timer Using IC NE 555
- Scr Controlled Emergency Light
FEATURES
The board consists of the following built in parts :
The board consists of the following built in parts :
- Three I.C. regulated D.C. power supplies internally connected.
- A.C. supply.
- Isolation Transformer.
- Timer I.C.
- Operational amplifier I.C.
- Quad dual Input NAND gate I.C.
- Pulse Transformer.
- Battery.
- D.C. Relay.
- OVEN with Power Supply.
- Thermometer 0-110 °C.
- Adequate no. of electronic components to be used in various experiments i.e. Pot 5 Nos., Push to on switch 2 Nos., Push to off switch, Buzzer, Bulb 230V40watt, Bulb 12V 5watt, LED 2Nos., Diode 4 Nos., Diac, Zener 2Nos., LDR, Thermistor, SCR 4 Nos., Triac, UJT 2 Nos, Transistors 3 Nos. Resistance & Capacitor 44No. etc. Main ON/OFF switch, fuse and jewel light.
- The Unit is operative on 230V, ±10% at 50Hz A.C. mains.
- Good quality, reliable terminals/Sockets are provided at appropriate places on panel for connections/ observations.
- Strongly supported by detailed Operating Instructions, giving details of Object, Theory, Design procedures, Report Suggestions and Book References.
- Patch cords are provided to make required connections.