TESCA
Quadrature Oscillator with Power Supply - Order Code 36289
- SKU:
- 36289
- Shipping:
- Calculated at Checkout
Frequently bought together:
Description
Order Code: 36289
Name: Quadrature Oscillator with Power Supply
SPECIFICATION
Experimental Training board has been designed specifically to study of quadrature oscillator. It produces sine wave 0 and cosine wave that are in out of phase by 90 .
Practical experience on this board caries great educative value for science and engineering students.
Object:
01. To study constructional features of quadrature oscillator.
02. To verify the generation of two signal (sine & cosine) that are in quadrature i.e. out of phase by 90 .
03. To study the variation in frequency by varying the values of components.
Features:
The board consists of the following built in parts :
01. ± 15V D.C. at 50mA. IC regulated power supply internally connected.
02. OP-Amp IC.
03. A selector switch provided to select three frequencies.
04. Two potentiometers for feed back control (coarse & fine control)
05. Adequate no. of other electronic components.
06. Mains ON/OFF switch, fuse and jewel light.
* Unit is operative on 230V ± 10% at 50 Hz A.C. mains
* Good quality, reliable terminals/sockets are provided at appropriate places on panel for connections/observations of waveforms.
* Strongly supported by detailed Operating Instructions, giving details of Object, Theory, Design procedures, Report Suggestions and Book References.
Practical experience on this board caries great educative value for science and engineering students.
Object:
01. To study constructional features of quadrature oscillator.
02. To verify the generation of two signal (sine & cosine) that are in quadrature i.e. out of phase by 90 .
03. To study the variation in frequency by varying the values of components.
Features:
The board consists of the following built in parts :
01. ± 15V D.C. at 50mA. IC regulated power supply internally connected.
02. OP-Amp IC.
03. A selector switch provided to select three frequencies.
04. Two potentiometers for feed back control (coarse & fine control)
05. Adequate no. of other electronic components.
06. Mains ON/OFF switch, fuse and jewel light.
* Unit is operative on 230V ± 10% at 50 Hz A.C. mains
* Good quality, reliable terminals/sockets are provided at appropriate places on panel for connections/observations of waveforms.
* Strongly supported by detailed Operating Instructions, giving details of Object, Theory, Design procedures, Report Suggestions and Book References.