TESCA
Measurement of power & power factor of L-R Circuits with power supply and 4 meters - Order Code 36244
- SKU:
- 36244
- Shipping:
- Calculated at Checkout
Frequently bought together:
Description
Order Code: 36244
Name: Measurement of power & power factor of L-R Circuits with power supply and 4 meters
SPECIFICATION
Experimental Training Board has been designed specifically for the Measurement of Power and Power Factor of R-L Circuit with a single phase of AC voltage source using voltmeters, current meter and a wattmeter.
Practical experience on this board carries great educative value for Science and Engineering Students.
Object:
Measurement of Power and Power factor of R-L circuit with a single phase of AC voltage source using voltmeters, current meters and wattmeter.
Features:
The board consists of the following built-in parts:
01. Mains transformer having tappings at 10V, 20V, 30V and 40V ± 10% AC at 500mA provided on terminals.
02. A.C. Ammeter, 65mm round dial to read 0-500mA.
03. Three A.C. Voltmeters, 65mm round dial to read 0-50VA.C.
04. Wire wound resistor 100W, 20W.
05. Inductor 200mH at 500mA rated current.
06. Mains ON/OFF switch, Fuse and Jewel light.
* The unit is operative on 230V ±10% at 50Hz A.C. Mains.
* Adequate no. of patch cords stackable from rear both ends 4mm spring loaded plug length ½ metre.
* Good Quality, reliable terminal/sockets are provided at appropriate places on panel for connections / observation of waveforms.
* Strongly supported by detailed Operating Instructions, giving details of Object, Theory, Design procedures, Report Suggestions and Book References.
Practical experience on this board carries great educative value for Science and Engineering Students.
Object:
Measurement of Power and Power factor of R-L circuit with a single phase of AC voltage source using voltmeters, current meters and wattmeter.
Features:
The board consists of the following built-in parts:
01. Mains transformer having tappings at 10V, 20V, 30V and 40V ± 10% AC at 500mA provided on terminals.
02. A.C. Ammeter, 65mm round dial to read 0-500mA.
03. Three A.C. Voltmeters, 65mm round dial to read 0-50VA.C.
04. Wire wound resistor 100W, 20W.
05. Inductor 200mH at 500mA rated current.
06. Mains ON/OFF switch, Fuse and Jewel light.
* The unit is operative on 230V ±10% at 50Hz A.C. Mains.
* Adequate no. of patch cords stackable from rear both ends 4mm spring loaded plug length ½ metre.
* Good Quality, reliable terminal/sockets are provided at appropriate places on panel for connections / observation of waveforms.
* Strongly supported by detailed Operating Instructions, giving details of Object, Theory, Design procedures, Report Suggestions and Book References.