Features:
| CATEGORY | SPECIFICATIONS |
|---|---|
| Product name | Mini DIY incubator accessories |
| Model | HTMC-5 |
| Features |
1. Exhaust fan for long-term, quiet incubation 2. PTC heating sheet for automatic constant temperature and energy saving3. Humidity probe: imported digital sensor with stable long-term performance4. Designed for DIY hatching experience |
| Panel size | 33.2 × 3 × 10.2 cm / 13.07 × 1.18 × 4.02 in |
| Rated power | 80W |
| Rated voltage | 220V |
| Egg turning frequency | 2 times per hour |
| Temperature control range | 37°C ~ 39°C |
| Scope of application | Supports 48, 56, 96, 112 eggs |
| Package size | 34.8 × 7 × 14 cm / 13.70 × 2.76 × 5.51 in |
Setting parameters temperature and humidity
- Test: After connecting the components as shown in the figure, turn on the power, you will hear the alarm sound caused by temperature and humidity, and manually cancel the alarm.
- Set the temperature and humidity, change the number of hatching days: Press the Set button, press "+/-" to select the desired temperature, set the humidity and hatching days in the same operation (repeat twice ) and finally hit the settings to exit the settings. (Note: The factory setting is 37.8 ° C, you can set 37.6 ° C according to the above method. After setting the hatching days, the machine reboots.)
- Low or high temperature alarm parameter setting: Press the setting button for 3 seconds, press "+/-", the screen will display "AL", then press the setting button, press "+/-" to select the low temperature parameter. Press the setting button for 3 seconds, the display shows "AH", and the high temperature alarm parameter is set as above.
- Humidity alarm parameter setting: humidity parameter is set to 45% when done and does not need reset. (If you need to set it according to the temperature parameter setting mode, the display shows "AS").
- Temperature sensor report calibration: Normal temperature report is set to 0 ° C. If not correct, it can be set. The method is the same as above, and the display shows "CA".)
- To set upper or lower limit temperature: if the HS (upper limit set) is set to 38.2 and LS (lower limit set ) is 37.4, the original temperature can only be changed from 38.2 to 37.4, and the lower limit should be 37.2.
- Heating Element Configuration: HU and HD parameters are factory set and no reset is required.
Package Includes:
- 1 x electric fan
- 1 x heated blade
- 1 x charging wire
- 1 x panel
- 1 x humidity probe
- 1 x temperature probe
- 1 x interface motor
- 1 x egg motor