Orange
1/2" DN15 Brass Motorized Ball Valve - 12V OP05 Female BSP
- SKU:
- PEESV84
- Shipping:
- Calculated at Checkout
Description
Features
1.Precision metal gear, high strength, reliable performance, long service life
2.Multiple wiring for remote control and valve status feedback to intelligent control unit
3.Floating sealing ball valve, no leakage
4.Low power consumption, battery workable
5.Flame retarded PC-ABS enclosure with compact, exquisite structure
6.IP 67 protection, applicable for humid environment
7.With visual position indicator
8.Various connectors customizable
9.Manual override for option
Application
Automatic remote fluid control for a variety of scenarios, such as smart home, water treatment project, smart water measuring system, fire sprinkler system, water supply and drainage system etc.
Technical parameters
Series | Torque | Operating time | Working voltage | Working current | Max power | Max pressure | Medium temperature | Ambient temperature |
FH | 2.5 N.M | <5s | 5V DC,9-24V AC,9-35V DC,110-230V AC | <100mA | 5W | 1.0MPa | 0-100℃/
32-212℉ |
-20--45℃ /-4 -113℉ |
Humidity | Enclosure | Service life | Wiring | |||||
95% | IP67 | 50,000-80,000 times |
OP01, OP02, OP03, OP04, OP05 optional |
Dimension Unit:mm
DN | D1/D2 |
φd |
L1 | L2/L3 | F | H1 | H2 | W(kg) |
DN8 | G1/4'' | 8 | 45 | 10 | 21 | 68 | 42 | 0.4 |
DN15 | G1/2'' | 15 | 57 | 11 | 25 | 71 | 42 | 0.5 |
DN20 | G3/4'' | 20 | 63 | 12 | 31 | 74 | 42 | 0.6 |
DN25 | G1'' | 25 | 73 | 16 | 37 | 77 | 42 | 0.8 |
Instruction for manual override
1. Manual override function is usually for occasions such as power outage, commissioning etc.
2. Lift the hand-wheel up, observe the open angle through the position indicator, rotate the hand-wheel until the valve is in place.
3.Press down the hand-wheel to switch back to automatic control
Wiring cautions
Make sure that the voltage of power supply meets the requirement of the actuator. The wiring should comply with local standards and operated by qualified personnel. When installing or repairing, the power should be cut off to prevent electric shock and damage to the equipment. For the illustration below, the valve is normally closed by default.
OP01
1. Set SW to [OPEN], the electric valve opens, and it stays in position after it is fully opened.The valve is de-energized (no power consumption).
2. Set SW to [CLOSE], the electric valve closes, and it stays in position after it is fully closed. The valve is de-energized (no power consumption).
In case of power loss, valve will remain in its current state.
Voltage of power supply for option:5V DC/ 9-35V DC
OP02
- 1.Both AC and DC power supply workable, while powered with DC power supply,connect the black wire to the (-) pole of power source.
- 2. Set SW to [OPEN], the electric valve opens, and it stays in position after it is fully opened.The valve is de-energized (no power consumption).
- 3. Set SW to [CLOSE], the electric valve closes, and it stays in position after it is fully closed. The valve is de-energized (no power consumption).
In case of power loss, valve will remain in its current state.
Voltages for option:5V DC/ 9-35V DC/220V AC
OP03
1. Both AC and DC power supply workable for OP03. When the power supply is DC, connect red wire to the (+) pole and black wire to the (-) pole .
2. Turn the SW on, the electric valve opens, and it stays in position after it is fully opened.
3. Disconnect the SW, the electric valve closes, and it stays in position after it is fully closed.
Voltages for option:5V DC/9-24V ADC/220V AC
OP04
1. Both AC and DC power supply workable. Normal Closed type Control.
2. Turn the SW on, the electric valve opens, and it stays in position after it is fully opened. There is nominal power consumption.
3. Disconnect the SW (or the power is lost for any other reason ), the electric valve closes.
Voltages for option:5V DC/ 9-24V ADC/110-230V AC
OP05
1. Set SW to [OPEN] - the red wire connect to the (+) pole of power supply, the black wire connect to the (-) pole of power supply, and connect the green wire with fully-open control terminal on the control device, the yellow wire with fully-closed control terminal, white wire is the common wire, when the electric valve fully opens, the green wire outputs valve-fully-open signal, with signal received, the SW is set to switch to STOP position, the valve stops action and keeps in fully open position.
2. Set SW to [CLOSE] - the red wire connect to the (-) pole of power supply, the black wire connect to the (+) pole of power supply, and connect the green wire with fully-open control terminal on the control device, the yellow wire with fully-closed control terminal, white wire is the common wire, when the electric valve fully closes, the yellow wire outputs valve-fully-closed signal, with signal received, the SW is set to switch to STOP position, the valve stops action and keeps in fully closed position.
Package Includes
1/2" DN25 Brass Motorized Ball Valve - 12V OP05 Female BSP